09/2016 Page 42 5IN2371 C
Defining Zone Parameters using the “One-By-One” Option
This option lets you to define all zone parameters, for one zone at a time.
To define zone parameters using the One-By-One option:
1. From the installer Programming menu go to: 2 > 1 > 1 (Zones > Parameters >
One by One); a zone number (i.e. Z=001) displays in the format described above.
2. Using the scroll keys, enter another 3-digit zone number (for the next zone that
you want to define its parameters), then press OK ( ). If (—:———:——)
displays, it means the zone hasn’t been allocated (parameters can’t be defined).
3. You can now define the following parameters for this specific zone (moving
from one parameter type to another by pressing ):
a. [Labels]: You can give the zone a descriptive “label” by typing over the
default “ZONE” (see Designating Labels, page 26), and then press .
b. [Partitions]: To select partitions (up to 32) to associate with the zone, scroll
to the partitions, which are grouped in blocks: the first block contains
partitions 01—08 (the default) if that is what was enabled. If additional
partitions were enabled, scroll to all the blocks (of ten) they are located in:
block 01—10, 11—20, 21—30, and 31—32. In each block, enter the relevant
partition number/s (each will display as P=#) and then before pressing ,
scroll to the next blocks and do the same. When finished, press .
c. [Group]: For applicable group/s (a specific area that can be armed within a
specific partition – up to 4 groups [A—D] maximum per each partition).
For each group letter, toggle with between Y (select) and un-select,
then scroll to the next group letter, if needed. When finished press .
d. [Zone Type]: Scroll to select the zone type (35 zone types – see the ProSYS
Plus Installation Manual for descriptions) and then press .
e. {Arm Sound]: Scroll to select an arming sound, and then press .
Options: silent, bell only, buzzer only, bell+buzzer, door chime.
f. [Stay (Partial Arm) Sound]: Scroll to select a partial arming sound, then
press . Options: silent, bell only, buzzer only, bell+buzzer, door chime.
g. [Disarm Sound]: Scroll to select the disarming arm sound for this zone,
and then press . Options: silent, door chime.
h. [Terminate]: For wired relay-detector zones only. Scroll to select the zone
termination type, then press . Options: NC, EOL, DEOL, N/O, TEOL.
i. [Response]: Scroll to select zone response time, then press . Options:
NORMAL (400 ms), LONG (1 sec.), FAST
(10 ms), and E. FAST (1 ms).
4. Press to go to the next zone, and repeat the procedure for all other zones.