09/2016 Page 40 5IN2371 C
Sending Wireless Device RF Transmissions
Wireless devices
(1-way / 2-way)
To send an RF transmission:
Detectors :
WatchOUT
BWare
iWave
iWise
Door-Window Contacts
(Dual Channel, Pulse
Count, Universal)
Shock
Glassbreak
Insert battery. Press and hold the tamper switch for at least 3
seconds.
Smoke & heat detectors
Insert battery. Transmission is sent automatically within 10
seconds.
Gas detectors
Insert battery. Within 10 seconds, press and hold the test
button for 3 seconds.
CO detectors
Insert battery. Within 10 seconds, press and hold the test
button for 3 seconds.
Flood detectors
Insert battery. Press both tamper buttons (back and cover)
for at least 3 seconds.
WL beams
Insert battery. Press tamper spring for 5 seconds. Observe
DIP switch settings according to model and tamper usage.
Sirens (Round Indoor
siren, Lumin8 siren,
Outside sirens)
Insert battery. Within 10 seconds, press and hold the tamper
switch for 3 seconds.
2-way, 8-button remote
control
Press both buttons ( and ) for at least 7 seconds.
4-button rolling code
keyfob
Press and hold
for at least 5 seconds (the LED lights up
twice during the 5 seconds - the second time indicates the
transmission is being sent).
2-button panic keyfob Press both buttons for at least 7 seconds.
Wristband panic
transmitter
Press both buttons for at least 7 seconds. The red LED lights
up upon transmission.
2-Way WL Slim Keypad
Press and hold both buttons ( and ) for at least 2
seconds.