09/2016 Page 51 5IN2371 C
Changing the Default Grand Master Code
The default Grand Master code is 1234, which can be changed by the installer. Be
sure to advise the customer that that after system installation, the primary system
user (“Grand Master”) should change the Grand Master code to be unique and
confidential (refer to the ProSYS Plus User documentation).
To change the default Grand Master code:
1. From the installer Programming menu select 4)Codes > 2)Grand Master, and
then press OK ( ); **** displays
2. Scroll through the asterisks and enter a new code, and then press .
Defining Follow Me Destinations
You can enable and define multiple Follow-Me destinations.
NOTE: The actual telephone numbers and email addresses for FM destinations are
defined by the Grand Master in the User menu.
Enabling Follow Me
To enable using Follow Me destinations:
From the installer Programming menu go to: 1)System > 2)Controls >
3)Communication > 2)FM Enable, use to toggle to Y to enable (or to N to
disable), and then press OK ().
Defining Follow Me Parameters
To define parameters for a Follow Me destination:
1. From the installer Programming menu go to: 5)Communication menu >
4)Follow Me > 1)Define FM); Follow Me 01 displays (1st FM destination).
2. Scroll to a FM number to define, and then press .
3. Scroll through the following options and define them as needed: Report Type,
Partition, Events, Restore Events, Remote Control.
Defining System Timers
You can change the system defaults for the various system timers, as needed.
See the ProSYS Plus Installation and Programming Manual for details.
To define system timers:
1. From the installer Programming menu, select 1)System > 1)Timers
2. Scroll to select from the options and modify their parameters as needed.