09/2016 Page 37 5IN2371 C
Sounders (Sirens)
1. From the installer Programming menu, select 7> 1> 2, scroll to 08)Sounder, and
then press OK ().
2. Scroll to, and then edit the sounder’s physical ID number to match its DIP
switch settings (see Describing Installer-Set ID Numbers for Bus Devices, page 18).
3. Press to toggle to the type (or select NONE to cancel its allocation), and
then press .
4. Select the partition number(s) for the sounder. While scrolling through each
block of partitions, designate the partition(s) to allow operation via the keypad.
Enter a partition number to select it (it will display), or enter the number again
to clear it (it will not display).
5. Scroll to and select the partition number for the siren, and then press .
6. Select Y to enable the sound (or use to toggle to N), and then press .
7. Select Y or N for squawk sound, and then press .
8. Select Y or N for squawk strobe, and then press .
9. Repeat from step 2 for all additional sirens.
Bus Zones (Bus Detectors)
1. From the installer Programming menu, go to: 7>1>2>0>9 (Install > Bus Device >
Manual, and scroll to 09)Bus Zone) and then press OK ( ); the first available
(non-allocated) bus zone displays as per this example. Note that the empty
fields in the parenthesis indicate that the zone has not yet been allocated:
Select (-:- -- :- -)
017) ZONE 017
2. Scroll to the zone that you want to allocate the bus zone to, then press OK ( );
the following (example) displays:
BUS ZONE: (017)
(1:00:01) T=xxxx)
EXPLANATION:
1 is the bus line number
00 is the bus zone expander ID (1—32) that the bus detector is
connected to (00 means wired to a bus line at the main panel PCB)
01 is the installer-set physical ID number for the bus detector
T is the type (description).