09/2016 Page 53 5IN2371 C
Testing the System
It is important to fully test the system. Here are typical, recommended system tests.
See the ProSYS Plus Installation and Programming Manual for more test information.
Bus Test for bus communication quality. See page 31.
Background noise-level threshold & calibration for wireless devices. See page 45.
Wireless Communication Test for wireless devices. See page 46.
Walk Test (for zones) – during which you arm the system, and then enter the
protected area in order to trigger alarm events at each detector to ensure
operability. Go to: installer Maintenance menu > Walk test
Monitoring Station (MS) Test (see the ProSYS Plus Installation Manual)
GSM signal strength – go to installer Maintenance menu > Diagnostics > GSM >
Signal – and view the signal strength result (0—5).
Additional tests at installer Maintenance menu for keypads, sirens, strobes,
wireless, and diagnostics (including main battery test, and zone resistance test)
Follow-Me Test: After programming FM destination(s), go to: User Menu > Follow
Me > Test FM. Trigger an alarm activation (for example, as done during a Walk
Test), and see if the FM notification is received at the FM destination.
Installer Responsibilities for Assisting Clients
Here are some typical, recommended areas for you to assist the client:
Advise client to change the Grand Master code to one that is confidential
For RISCO Cloud-enabled communication, instruct users with Smartphones to
download the iRISCO App from the Apple App store or Android Play Store, and
ensure that a connection between the app and the system is established.
Instruct how to define user codes, proximity tags, and Follow-Me contacts.
Instruct how to do the following from keypads and keyfobs:
Full arm, partial arm, and disarm
Send a duress disarm (silent alarm) to the monitoring station
Activate a panic alarm
Check system status
Use SMS for remote operation
Operate Talk ‘n Listen