c.
When you return to the PT input screen,
the selected point name is entered in the
PT field, incremented by one. (As shown
in the right. If BC is selected, BC1
appears in the PT field; If A098 is
selected, A099 appears.)
Press [REC/ENT].
d.
A: If the PtID exists in internal memory,
its coordinate will be displayed on the
screen. Press [REC/ENT] to return.
B: If the inputted PtID does not exist, it
is required to input coordinate (as shown
on the right). Input the coordinate and
press [REC/ENT] to move the cursor to
the code item. Input the code, press
[REC/ENT] to save and quit.
e.
Return to PT inputting screen. Move the
cursor to next item.
The stack shows the last 20 point names used, in chronological order from last used to first used. Stacks
with the same type are covered.
2.8.6 Press [REC/ENT] without a Point Name
In some occasions of inputting PtID, a temporary coordinate that needn’t to be saved can be used. The
input coordinates are used in calculation. They are not saved in the database.
a.
In PT item, press [ENT] directly without
inputting its PtID.