IMPORTANT: ALWAYS MAKE SURE THAT THE ZERO POINT IS SET CORRECTLY!
There are three possible variants:
1. ZP = 0 and XP = 0 In this case, the movement after the START signal goes after a safety
query to X 0,00 and then in -Z direction until the STOP key is pressed. START-STOP operation
is possible while the vehicle is moving. Only when the STOP button is pressed does the move-
ment abort, after which X and Z are reset to the stop position.
2. ZP <> 0 XP = 0, therefore only one end position for Z is specied, no depth.
Here the movement goes directly after the START signal WITHOUT safety query to X 0.00 and
then in -Z direction to the end point Z P. Then a reset to X 0.2 and back to Z 0.00 takes place,
then the position for X and Z changes to the hold position.
3. ZP < 0 and XP < 0, so the values for length and depth are given here.
The control cuts fully automatically in several passes. After the START signal, the control rst
displays an overview of all the data for the individual passes. A new START command starts the
cut, STOP aborts the process. After the last pass has been completed, the X axis is moved to
+0.2 and the surface at the end of the workpiece is turned cleanly at. Then the stop position
is approached.