Test Report CMU
1100.4903.82 1.26 E–4
Item
No.
Description
Measure-
ment to
section
Min. Actual Max.
Measurement
uncertainty
Unit
TX Residual AM at 1500 MHz
CCITT, rms
0.02 %
TX Residual AM at 2200 MHz
CCITT, rms
0.02 %
TX Modulation characteristics
TX Modulation characteristics
carrier suppression, f
mod
= 10 kHz, f
RF
= 1000 MHz
40 dBc
TX Modulation characteristics
carrier suppression, f
mod
= 20 kHz, f
RF
= 1000 MHz
40 dBc
TX Modulation characteristics
carrier suppression, f
mod
= 20 kHz, f
RF
= 1000 MHz
40 dBc
TX Modulation characteristics
carrier suppression, f
mod
= 30 kHz, f
RF
= 1000 MHz
40 dBc
TX Modulation characteristics
carrier suppression, f
mod
= 60 kHz, f
RF
= 1000 MHz
40 dBc
TX Modulation characteristics
carrier suppression, f
mod
= 100 kHz, f
RF
= 1000 MHz
40 dBc
TX Modulation characteristics
carrier suppression, f
mod
= 135 kHz, f
RF
= 1000 MHz
40 dBc
TX Modulation characteristics
carrier suppression, f
mod
= 135 kHz,
f
RF
= 1000 MHz
40 dBc
RX Harmonics
RX 2nd harmonic at RF2 , f
IN
= 50
MHz, CMU frequency = 100 MHz
RX
harmonics
30 dBc
RX 2nd harmonic at RF2 fIN = 600
MHz, CMU frequency = 1200 MHz
30 dBc
RX 2nd harmonic at RF2 , f
IN
= 625
MHz, CMU frequency = 1250 MHz
30 dBc
RX 2nd harmonic at RF2 , f
IN
= 1100
MHz, CMU frequency = 2200 MHz
30 dBc
RX 3rd harmonic at RF2 , f
IN
= 50 MHz,
CMU frequency = 150 MHz
30 dBc
RX 3rd harmonic at RF2 , f
IN
= 400
MHz, CMU frequency = 1200 MHz
30 dBc
RX 3rd harmonic at RF2 , f
IN
= 420
MHz, CMU frequency = 1260 MHz
30 dBc
RX 3rd harmonic at RF2 , f
IN
= 730
MHz, CMU frequency = 2190 MHz
30 dBc
RX 2nd harmonic at RF4 IN , f
IN
= 50
MHz, CMU frequency = 100 MHz
20 dBc
RX 2nd harmonic at RF4 IN , f
IN
= 600
MHz, CMU frequency = 1200 MHz
20 dBc

Table of Contents