Configuration
R&S
®
FSW-K7
111User Manual 1173.9240.02 ─ 17
AF Center....................................................................................................................111
AF Start.......................................................................................................................111
AF Stop....................................................................................................................... 111
AF Span...................................................................................................................... 111
AF Full Span............................................................................................................... 112
AF Center
Defines the center frequency of the demodulated data to evaluate.
Remote command:
[SENSe:]ADEMod:AF:CENTer on page 258
AF Start
Defines the start frequency of the demodulated data to evaluate.
Remote command:
[SENSe:]ADEMod:AF:STARt on page 259
AF Stop
Defines the stop frequency of the demodulated data to evaluate.
The maximum AF stop frequency corresponds to half the demodulation bandwidth.
Remote command:
[SENSe:]ADEMod:AF:STOP on page 259
AF Span
Defines the span (around the center frequency) of the demodulated data to evaluate.
The maximum span is DBW/2.
Remote command:
[SENSe:]ADEMod:AF:SPAN on page 259