11.4.2.3
Configuring Input via the Analog Baseband Interface (R&S FSW-B71)
The following commands are required to control the Analog Baseband Interface
(R&S FSW-B71) in a remote environment.They are only available if this option is instal-
led.
For more information on the Analog Baseband Interface see the R&S FSW I/Q Ana-
lyzer User Manual.
Useful commands for Analog Baseband data described elsewhere:
INP:SEL AIQ (see INPut:SELect on page 184)
[SENSe:]FREQuency:CENTer on page 231
Commands for the Analog Baseband calibration signal are described in the R&S FSW
User Manual.
Remote commands exclusive to Analog Baseband data input and output
INPut:IQ:BALanced[:STATe]........................................................................................... 198
INPut:IQ:FULLscale:AUTO..............................................................................................198
INPut:IQ:FULLscale[:LEVel]............................................................................................ 199
INPut:IQ:TYPE.............................................................................................................. 199
CALibration:AIQ:DCOFfset:I............................................................................................200
CALibration:AIQ:DCOFfset:Q.......................................................................................... 200
[SENSe:]PROBe<ch>:SETup:CMOFfset.......................................................................... 201
TRACe:IQ:APCon[:STATe]............................................................................................. 201
TRACe:IQ:APCon:A....................................................................................................... 201
TRACe:IQ:APCon:B....................................................................................................... 202
TRACe:IQ:APCon:RESult?............................................................................................. 202
INPut:IQ:BALanced[:STATe] <State>
This command defines whether the input is provided as a differential signal via all 4
Analog Baseband connectors or as a plain I/Q signal via 2 simple-ended lines.
Parameters:
<State> ON
Differential
OFF
Simple-ended
*RST: ON
Example:
INP:IQ:BAL OFF
Manual operation: See "Input configuration" on page 72
INPut:IQ:FULLscale:AUTO <State>
This command defines whether the full scale level (i.e. the maximum input power on
the Baseband Input connector) is defined automatically according to the reference
level, or manually.