Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
265User Manual 1173.9240.02 ─ 17
Parameters:
<FilterType> 5PCT | 10PCT | 25PCT
*RST: 25PCT
Example:
FILT:LPAS:FREQ:REL 25PCT
Selects the low pass filter as 25 % of the demodulation band-
width.
Manual operation: See "Low Pass" on page 114
[SENSe:
]FILTer<n>:LPASs[:STATe] <State>
This command activates/deactivates the selected low pass filter for the specified evalu-
ation.
For details on the low pass filter refer to "Low Pass" on page 114.
Parameters:
<State> ON | OFF
*RST: OFF
Example:
FILT:LPAS ON
Activates the selected low pass filter.
Manual operation: See "Low Pass" on page 114
11.4.8.5 Defining the Scaling and Units
The scaling parameters define the range of the demodulated data to be displayed.
11.4.8.6 Scaling for AF Evaluation
These settings are only available for AF evaluations.
Useful commands described elsewhere:
● [SENSe:]ADJust:SCALe:Y:AUTO[:CONTinuous] on page 269
● [SENSe:]ADEMod<n>:AF:COUPling on page 255
● DISPlay[:WINDow<n>]:TRACe:Y[:SCALe]:RPOSition on page 239
● DISPlay[:WINDow<n>]:TRACe:Y:SPACing on page 239
Specific commands:
DISPlay[:WINDow<n>]:TRACe:Y[:SCALe]:RVALue...........................................................265
DISPlay[:WINDow<n>]:TRACe:Y[:SCALe]:RVALue <Value>
This command defines the reference value assigned to the reference position in the
specified window. Separate reference values are maintained for the various displays.
Configuring the Measurement