EasyManuals Logo

Rosemount 3051SFC_A User Manual

Rosemount 3051SFC_A
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #156 background imageLoading...
Page #156 background image
Reference Manual
00809-0100-4809, Rev DA
Appendix A: Specifications and Reference Data
September 2015
148
Specifications and Reference Data
1. Not available for Primary Element Technology C.
2. For the 10-in. (250 mm) and 12-in. (300 mm) line size, the alignment ring must be ordered (Installation Accessories).
3. 10-in. (250 mm) and 12-in. (300 mm) line sizes not available with Primary Element Technology A.
4. For 2-in. (50 mm) line sizes the Primary Element Type is 0.6 for Primary Element Technology Code C.
5. Available with Primary Element Technology A only.
6. HART Revision 5 is the default HART output. The Rosemount 2051 with Selectable HART can be factory or field configured to HART Revision 7. To order
HART Revision 7 factory configured, add option code HR7.
7. Not available with Low Power Output Code M.
8. Only available with output code X.
9. Available with primary element technology C only.
10. Available with primary element technology C or A only.
11. For Annubar Option A, consult factory for pipe schedules other than Sch. 40.
12. Available with primary element technology C or P only.
13. Only valid with F
OUNDATION Fieldbus Output Code F.
14. Only available with 4-20 mA HART output (output code A).
15. Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental
limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
16. Not available with Primary Element Technology P.
17. Not available with output code X.
18. Not available with F
OUNDATION Fieldbus (Output Code F) or Wireless (Output Code X).
19. Not available with Housing code 00, 5A, or 7J. The T1 option is not needed with FISCO Product Certifications, transient protection is included with the FISCO
Product Certification code IA.
20. Only available with 4-20 mA HART (output codes A and M).
21. NAMUR-compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
22. Only available with HART 4-20 mA (Output Codes A and M) and Wireless (Output Code X).
23. The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
24. Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
25. Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if 14 needed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosemount 3051SFC_A and is the answer not in the manual?

Rosemount 3051SFC_A Specifications

General IconGeneral
BrandRosemount
Model3051SFC_A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals