MAINTENANCE MANUAL LINE
Contaminated
ATTENTION
If the oil circuit is contaminated, replace the oil cooler and flush the oil circuit.
See chapter 12–20–00 section: Flushing the oil circuit. Proper judgement re-
quires years of experience in repair of piston engines.
AE_912i_0092
2
3
1
4
5
5
from oil pump
to bearings
Figure 7.22: Oil filter
1
Filter housing
2 Filter cover
3
Gasket ring
4 Anti-drain membrane
5 Filter matt