MAINTENANCE MANUAL LINE
Step
Procedure
7
Fit radiator cap.
8
NOTE
Run the engine briefly and replenish with clean coolant as required.
FLUSHING THE COOLING SYSTEM
General note
m WARNING
Risk of Burns!
Never open the radiator cap when the cooling system is hot. For safety’s sake, cover
cap with a rag and open slowly. Sudden opening of the cap could provoke the escape
of boiling coolant and result in scalding.
Instruction To flush the coolant the following steps are necessary:
Step
Procedure
1
The system is flushed using pure water at a pressure of 2 bar (29 psi).
NOTE
For the flushing, open the lowest located coolant hose (either at
water pump or radiator).
2 Refill newly mixed coolant into the expansion tank (highest point of the cool-
ing system).
See Chapter 12-10-00 section Coolant check/replenish.
ATTENTION
Where water-free coolant is used, the cooling system must be flushed and re-
filled with conventional coolant.
Step
Procedure
3 Fit radiator cap.
4
NOTE
Run the engine for a minute and replenish coolant as required.