MAINTENANCE MANUAL LINE
EXCEEDING OF MAX. COOLANT TEMPERATURE
General note
ATTENTION
If the maximum coolant temperature is exceeded, other limits are also often ex-
ceeded, e.g. oil temperature. Please observe the relevant instructions.
NOTE
Any exceeding of the max. admissible coolant temperature must be entered by
the pilot into the engine log book, stating duration, extent of excess temperature
and pertinent detail.
Proceed as instructed
in table 2
Proceed as
instructed in table 1
30 min.
135°C
(275 °F)
Operating limit
(See Operators Manual 912 i Series)
0 Time
Figure 5.12: Overview and proceed:
Temperature exceeded briefly
05–50–00
Page 20
September 01/2018
Effectivity: 912 i Series
Edition 2/Rev. 0

Table of Contents

Other manuals for Rotax 912 i series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 912 i series and is the answer not in the manual?

Rotax 912 i series Specifications

General IconGeneral
Number of Cylinders4
Max Power100 hp (73.5 kW)
Max Power Output RPM5800 rpm
Ignition SystemDual electronic ignition
Oil SystemDry sump, forced lubrication with separate oil tank
Reduction Gear Ratio2.43:1
TBO2000 hours
Engine Type4-stroke, horizontally opposed
Displacement1352 cm³
Bore x Stroke84 mm x 61 mm
Max Torque128 Nm
Fuel TypeAvgas 100LL or unleaded automotive gasoline