EXCEEDING THE MAX. PERMISSIBLE OIL TEMPERATURE
General note
ATTENTION
If the max. permissible oil temperature is exceeded, other limits are often ex-
ceeded, too, e.g. the cylinder head temperature. Please observe the relevant
instructions.
NOTE
Any exceeding of the max. admissible oil temperature must be entered by the pilot
into the engine log book, stating duration extant of excessive temperature and
pertinent detail.
Read out the ECU data memory and check the data for details of increased oil tempera-
ture. Perform the corresponding inspections/repairs depending on the functional defects
found.
Proceed as instructed
in table 4
Proceed as instructed
in table 3
Operating limit
(See Operators Manual 912 i Series)
160 °C
(320 °F)
0
15 min. Time
Figure 5.13: Overview and proceed
Effectivity: 912 i Series
Edition 2/Rev. 0
05–50–00
Page 23
September 01/2018

Table of Contents

Other manuals for Rotax 912 i series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 912 i series and is the answer not in the manual?

Rotax 912 i series Specifications

General IconGeneral
Number of Cylinders4
Max Power100 hp (73.5 kW)
Max Power Output RPM5800 rpm
Ignition SystemDual electronic ignition
Oil SystemDry sump, forced lubrication with separate oil tank
Reduction Gear Ratio2.43:1
TBO2000 hours
Engine Type4-stroke, horizontally opposed
Displacement1352 cm³
Bore x Stroke84 mm x 61 mm
Max Torque128 Nm
Fuel TypeAvgas 100LL or unleaded automotive gasoline
Fuel SystemElectronic fuel injection
Cooling SystemLiquid/air-cooled