MAINTENANCE MANUAL LINE
ABBREVIATIONS AND TERMS
Abbreviations Description
* Reference to another section
@
center of gravity
The drop symbol indicates use of sealing agents, adhesives or lubri-
cants (only in the Illustrated Parts Catalog).
°C Degrees Celsius (Centigrade)
°F
Degrees Fahrenheit
rpm
Revolutions per minute
A Ampere
AAPTS Ambient Air Pressure Temperature Sensor
AC
alternating current
AD Airworthiness Directives
Ah Ampere hour
A/C Aircraft
AR as required
assy.
assembly
ASB Alert Service Bulletin
ACG Austro Control GmbH
ACL Anti Collision Light
API American Petrol Institute
ASTM American Society for Testing and Materials
ATA Air Transport Association
AWG American Wire Gauge
CAN Controller Area Network
Coil 1–4
Ignition coils 1–4
CPS 1+2 Crankshaft Position Sensor 1+2
CSA Constant Speed Actuator
CTS Cooling Temperature Sensor
CW
clockwise
CCW
counter-clockwise
CGSB Canadian General Standards Board
Effectivity: 912 i Series
Edition 2/Rev. 0
00–00–00
Page 5
September 01/2018

Table of Contents

Other manuals for Rotax 912 i series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 912 i series and is the answer not in the manual?

Rotax 912 i series Specifications

General IconGeneral
Number of Cylinders4
Max Power100 hp (73.5 kW)
Max Power Output RPM5800 rpm
Ignition SystemDual electronic ignition
Oil SystemDry sump, forced lubrication with separate oil tank
Reduction Gear Ratio2.43:1
TBO2000 hours
Engine Type4-stroke, horizontally opposed
Displacement1352 cm³
Bore x Stroke84 mm x 61 mm
Max Torque128 Nm
Fuel TypeAvgas 100LL or unleaded automotive gasoline
Fuel SystemElectronic fuel injection
Cooling SystemLiquid/air-cooled