EbV Product documentation THETA NORM/UNIT
8-20
CAUTION In order to measure the room temperature the heating circuit of the most occupied
room is to be used.
Radiator thermostats are used together with correctly designed radiators to control
the external heat gain and should hence be almost completely open. During the
adjustment phase additional external heat sources like fireplaces, majolica stoves,
etc. should not be used. Furthermore, during the measurement period excessive
ventilation is to be avoided.
The measurement period covers basically the heating phases. If the heating
characteristic is correctly set, the room temperature remains constant according to
the set daytime setpoint regardless of the changes in the outside temperature.
NOTE: The heating characteristics are limited by the minimum and maximum temperature
limits. With activated limits the relevant flow temperature is controlled exclusively
according to the set limit values.
Operation:
Note on operation Key / parameter tree Parameter
Setting Heating curve slope
£.
Boiler /flow temperature (°C)
T
R
o
o
m
(
°
C
)
Outdoor temperature (°C)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotex Controller Series and is the answer not in the manual?

Rotex Controller Series Specifications

General IconGeneral
BrandRotex
ModelController Series
CategoryController
LanguageEnglish

Related product manuals