82 April 2015 IMO_374_EN_v1 Roto Patio Fold Subject to change.
Maintenance
Inspection and care
Inspection
At least annually, every six months for school and hotel buildings:
Specialist
company
End-users
Check that safety-relevant hardware
components are mounted securely.
Examine safety-relevant hardware
components for wear and tear.
All movable parts are to be operation-tested.
All locking points are to be operation-tested.
The hardware’s smooth operation can be
checked by means of moving the window
handle.
In accordance with DIN18055, the locking
and unlocking moment is max. 10Nm.
It can be checked using a torque wrench.
The smooth operation can be improved by
greasing/oiling or adjusting the hardware.
= To be carried out only by a specialist company
= Not to be carried out by the end-user; the end-user may not carry out installation work!
= To be carried out either by a specialist company or by the end-user.
Care
Specialist
company
End-users
Keep the hardware free from deposits and
soiling.
Never use aggressive, acidiferous cleaners or
abrasive cleaning agents.
Only use mild, pH-neutral cleaning agents in
diluted form.
Only use a soft cloth for cleaning.
= To be carried out only by a specialist company
= Not to be carried out by the end-user; the end-user may not carry out installation work!
= To be carried out either by a specialist company or by the end-user.
No legal claims can be derived from these recommendations, the
application is to be conveyed for each concrete individual case. The
window and balcony door manufacturer must draw builders and end-user’s
particular attention to these maintenance instructions. Roto Frank AG
recommends window fabricators to make maintenance agreements with
their end-users.