For experienced Users: AT commands
68 SAGEM RT3000
Datei 8115AD002-Total.doc
Datei gespeichert 24.04.04 13:23 von EDV/ORGA
Druckzeit 24.04.04, 18:17
Status Release
Command Function (factory setting in bold print)
cope with data loss
2: Non real-time traffic, error-sensitive application that can
cope with infrequent data loss
3: Non real-time traffic, error-sensitive application that can
cope with data loss, GMM/SM, and SMS
4: Real-time traffic, error-sensitive application that can cope
with data loss
5: Real-time traffic, error non-sensitive application that can
cope with data loss
peak = numeric parameter for the peak throughput class
0: network subscribed value
1: Up to 1000 (8 kbit/s)
2: Up to 2000 (16 kbit/s)
3: Up to 4000 (32 kbit/s)
4: Up to 8000 (64 kbit/s)
5: Up to 16000 (128 kbit/s)
6: Up to 32000 (256 kbit/s)
7: Up to 64000 (512 kbit/s)
8: Up to 128000 (1024 kbit/s)
9: Up to 256000 (2048 kbit/s)
mean = a numeric parameter which specifies the mean
throughput class
AT+CBST=
[speed
[,name
[,ce ]]]
Select bearer service type. This command selects the bearer
service name with data rate speed, and the
connection element ce to be used when data calls are originated.
speed =
0 autobauding (automatic selection of the speed; this
setting is possible in case of 3.1 kHz modem and non-
transparent service)
4 2400 bps (V.22bis)
6 4800 bps (V.32)
7 9600 bps (V.32)
68 2400 bps (V.110 or X.31 flag stuffing)
70 4800 bps (V.110 or X.31 flag stuffing)
71 9600 bps (V.110 or X.31 flag stuffing)
name =
0 data circuit asynchronous (UDI or 3.1 kHz modem)
1 data circuit synchronous (UDI or 3.1 kHz modem)
ce =
0 transparent
1 non-transparent