SAM4S ER-230EJ Manual Service Mode 77
Self Test
Various components of the ER-230EJ are tested by using this program.
1. From SERVICE MODE menu press 1 and CASH to display the SELF TEST
menu:
SELF TEST
1. BATCH TEST
2. PRINTER
3. DISPLAY
4. KEYBOARD
5. INTERFACE
6. RTC
7. BATTERY
2. Press the key and the key to select menu and press the CASH key to
confirm.
3. Press the digit representing the test you wish to perform.
Memory Clear
Before you use your ER-230EJ for the first time, you must perform a memory all clear to
insure that all totals and counters are cleared and that the default program is installed. Go
to Clearing Memory on page 25 to complete this procedure.
1. From SERVICE MODE menu press 2 and CASH to display the MEMORY
CLEAR screen:
Press the key and the key to select menu and press the CASH key to
confirm.
MEMORY CLEAR
1. CLEAR TOTAL
2. CLEAR GRAND
3. CLEAR PLU
4. CLEAR PRICE=0
5. EDIT COUNTERS
6. NON MOVER CLR
2. Press the key and the key to select menu and press the CASH key to
confirm.
3. To clear total, press 1 the CASH. The screen asks: ARE YOU SURE?
ARE YOU SURE?
Y=CASH N=CLEAR
4. Press the CASH for YES or the CLEAR for NO.
5. The message "ALL TOTAL CLEAR" is printed and the screen returns to the
SERVICE MODE menu.