SECTION V MAINTENANCE
Condenser fins must always be duly clean. Cleaning should be done using
water or an air jet (pay particular attention not to bend the fins, if necessary
straighten the fins again using a special tool).
Ascertain that the compressor is firmly secured to tractor and the pulleys
are properly aligned.
WARNING
- When removing the strainer or the air conditioning unit it is
necessary to plug the inlet and oulet pipes at once, this to prevent both
dust and moisture from entering the system.
Air conditioning system compressor
The compressor must be securely fixed to the tractor.
The refrigerant circuit is pressurised and therefore must never be opened.
The ecological refrigerant R 134a is non-toxic and odourless, and is not
inflammable.
However, there are certain
essential safety precautions
when handling refrigerant:
•
Avoid direct contact with
skin, as this can cause le-
sions similare to chilblains
•
Avoid contact with eyes;
should the refrigerant enter
your eyes, seek medical
assistance immediately.
•
Any welding either directly
on the refrigerant circuit or
in the immediate vicinity is
strictly prohibited. The re-
frigerant must not be be ex-
posed to temperatures in
excess of 80°C (176°F).
Air conditioning system
This is located in the cab roof.
Slacken off the two retaining
screws and lift off the cover to
access the air conditioning
system.
154