SECTION IX FAULT DIAGNOSIS
The lift is only partially raised
Check lift adjustments.
The lift is lowered too slowly
Check that the “lowering” valve is not sticking.
The lift oscillates rhythmically
Check adjustment and pressure relief valve settings.
When the lift arms are raised to maximum height, the pressure relief valve
discharges continuously
Check adjustment.
Control valve spool worn (with internal leaking).
Auxiliary hydraulic systems
Implements connected to the hydraulic system do not operate correctly
Implements not suited to characteristics of the hydraulic system.
Fault in the hydraulic lift system. See lift unit.
Incorrect type/quantity of oil in the circuit: change and/or top up trans-
mission oil.
Oil filters clogged: renew filters.
Oil pump worn or defective: overhaul or replace as necessary (opera-
tions to be carried out by a specialised service centre).
Safety valve setting incorrect:
Check valve pressure setting and adjust if necessary (operations
to be carried out by a specialised service centre).
Incorrect adjustment of control levers:
Adjust (operations to be carried out by a specialised service centre).