Base circuit test
Step 1:
Open the 2-gun block (activate the 2 outputs of the block).
Open the guns.
Fluid can flow out while the pressure drops and then it should stop.
If this is not the case, then it means that a color changer is not waterproof.
If the color changers are sealed, proceed to step 2, otherwise make the necessary repairs.
The colour of the flowing product can identify the defective valve.
Close the 2-gun block.
Step 2:
Open a valve on the base side of the color changer.
A pressure build-up occurs between the color changer and the 2-gun block that can cause momentary
pulses.
If the 2-gun block is tightly sealed, then no product should flow out, so the flowmeter indicator A should be
steady (white or green).
However, if it is not sealed, then fluid will come out of the gun and the A flow meter light will flash.
Cata circuit test
Step 1:
Open the injection valve.
Open the 2-gun block (activate the 2 outputs of the block).
Open the guns.
Fluid can flow out while the pressure drops and then it should stop.
If this is not the case, then it means that a color changer is not waterproof.
If the color changers are sealed, proceed to step 2.
If no, make the necessary repairs.
The colour of the flowing product can identify the faulty valve.
Close the injection valve.