7. Troubleshooting
Default
wording
Automatic
action
Expected
validation
Action following
to validation
Trigger Causes Remedies
B/A ratio error -
Low limit
Closing of all valves
(CTM, Injection,
Gun) Display of the
default on the
screen
Passage
Validation
by the user
Switching to the regene-
ration mode and then pro-
duction
The B/A ratio mini-
mum tolerance has
been reached. (Not
enough B product).
Incorrect setting
of the ratio tole-
rance.
The supply pres-
sure of the B
component is too
low.
Incorrect gain
setting or too
much flow.
The injector is too
small.
Th injector of the
B component is
clogged or
damaged. The B
flowmeter is
defective.
Check the B/A
ratio tolerance.
Change if neces-
sary with a mini-
mum of + /- 1%.
Increase the sup-
ply pressure of B
component while
maintaining a
delta of pressure
of about 15%
between the B
product pressure
and the A pro-
duct pressure.
Check the correct
operating of the
flowmeter and
the sensor.
Clean and replace
if necessary.
Check the correct
operating of the
flowmeter and
the sensor.
Clean and replace
if necessary.
B/A ratio error -
High limit
Closing of all valves
(CTM, Injection,
Gun)
Display of the
default on the
screen
Validation
by the user
Switching to the regene-
ration mode and then pro-
duction
The B/A ratio maxi-
mum tolerance has
been reached (Too
much B compo-
nent).
Incorrect setting
of the ratio tole-
rance.
The supply pres-
sure of the B
component is too
high.
Incorrect gain
setting or too
much flow.
The injector has a
too large diame-
ter.
The B flowmeter
is defective.
Check the B/A
tolerance.
Change if neces-
sary with a mini-
mum of + /- 1%.
Reduce the sup-
ply pressure of
the B component.
Check and adjust
if necessary.
Replace the injec-
tor with a smaller
one.
Check the correct
operating of the
flowmeter and of
the sensor. Clean
and replace if
necessary.
Maximum flow error Display of an alarm
message
NO The flow rate is
higher than the
programmed maxi-
mum flow rate.
Leak in the circuit.
No tip on the gun
or the tip is worn
out. Pressure on
the fluid regula-
tor at gun is too
high.
Check for leaks
(static mixer, fit-
tings, seals,...).
Repair and/or
replace. Check
that the tip is
present and not
worn. Adjust the
fluid pressure at
the gun.

Table of Contents