1.5.1. Installation rules
The installation of any system that does not comply with the rules specified below is strictly prohibited.
Environment
Environmental risks must be controlled in the following manner:
• Have a qualified electrician check for ground continuity. If ground continuity is not assured, check the terminal,
wire and grounding point. Never operate the equipment until this problem is resolved.
• The materials to be painted must also be grounded by means of clamps equipped with cables or, if they are
suspended, by means of hooks that must remain clean at all times.
• Respect the average temperature of use of equipment and products, which must be at least 5°C lower than
the flash point of the products and within a range of 0 to 40°C.
• Ventilation of the area by forced extraction and supply of unpolluted air shall be mandatory during equipment
use or cleaning operations.
• Fragile parts of the installation, especially the hoses, must be protected from mechanical or thermal damage
during production or maintenance.
• The waste related to the operations or the dismantling of the equipment will have to be treated according to
the laws in force.
• The noise level of our equipment is limited to the maximum.
• Depending on the operating conditions, the sound pressure of the equipment may cause hearing damage.
• Take appropriate measures to reduce noise pollution.
• Dispose of packaging materials in a proper and environmentally friendly manner.
CAUTION Danger to personnel from improper installation.
• The exact delimitation of the zones is the express responsibility of the user, depending on the products used,
the environment of the equipment and the conditions of use.
• Select the pump so that the fluid pressure delivered by the pump is appropriate for the type of gun selected.
• Using a high pressure hose, connect the paint fitting on the gun to the pump. Tighten the fittings.
• The pressure resistance of the hose must be equal to or greater than the pressure delivered by the pump.