143
Member of Exel group
DRT582165110
A - 2023/03
Minimum flow error Display of an alarm
message
NO 1 or 2 guns are
opened and the
flow rate is lower
than the minimum
programmed flow
rate.
Nozzle clogged
Fluid supply
pressure too low
Check the tip.
Check that the
pressures are
sufficient.
A flow / trigger
error
Closing of all valves
(CTM, Injection,
Gun)
Display of the
default on the
screen
Validation
by the user
Swiching to regeneration
mode if the machine was
in production or restarting
priming process if the
machine was in the «Pri-
ming» phase
The dispenser of
the robot sends the
open gun informa-
tion but the PLC
does not receive a
lulse from the A
flowmeter within
the set time inter-
val
(Gun trigger time
without paint)
Defective dispen-
ser.
The painter trig-
gers the gun only
with air.
The A flowmeter
is blocked, the
sensor cable is
not properly
connected or the
sensor is defec-
tive.
Check the
absence of air
leakage, check
the correct
tightness of fit-
tings, check the
dispenser. Check
the correct ope-
rating of the input
on the card.
Inform the pain-
ter not to pull the
trigger without
letting the pro-
duct flow or
change the '' Air
Gun Trigger'' set-
ting.
Check the
flowmeter. Make
sure the gears
are turning freely.
Check the correct
operating of the
sensor. Repair or
replace.
A flow / trigger
error
Closing of all valves
(CTM, Injection,
Gun)
Display of the
default on the
screen
Validation
by the user
Swiching to regeneration
mode if the machine was
in production or restarting
priming process if the
machine was in the «Pri-
ming» phase
The dispenser of
the robot sends the
open gun informa-
tion but the PLC
does not receive a
pulse from the A
flowmeter within
the set time inter-
val
(Gun trigger time
without paint)
Defective dispen-
ser.
The painter trig-
gers the gun only
with air.
The A flowmeter
is blocked, the
sensor cable is
not properly
connected or the
sensor is defec-
tive.
Check the
absence of air
leakage, check
the correct
tightness of fit-
tings, check the
dispenser. Check
the correct ope-
rating of the input
on the card.
Inform the pain-
ter not to pull the
trigger without
letting the pro-
duct flow or
change the '' Air
Gun Trigger'' set-
ting.
Check the
flowmeter. Make
sure the gears
are turning freely.
Check the correct
operating of the
sensor. Repair or
replace.
Default
wording
Automatic
action
Expected
validation
Action following
to validation
Trigger Causes Remedies