11-7
11.4 Analog Output
Group Display Parameter Name Setting Range Default Unit
I/O group
I50 [Analog output item select] -
0 ~ 3 0
I51
[Analog output level
adjustment]
- 10 ~ 200 100 %
Output item and the level from the AM terminal are selectable and adjustable.
I50: The selected item will be output on the Analog output terminal (AM).
I50
Analog output
item select
Item corresponding to 10V
200V
400V
0 Output frequency. Max Frequency (F21)
1 Output current
150% of Inverter rated
current
2 Output voltage 282Vac 564Vac
3
Inverter DC link
voltage
400Vdc 800Vdc
I51: If you want to use Analog output value as an input signal for instruments, the value can be
adjustable according to instruments specifications.