246
[Supplementary Explanation3]
• Parameter part to be followed by Data part. Data part and data part should be specified in a row.
When do not specify in a row, print result may not be secured.
Micro QR Code Data size list
Version Error correction Numeric Alphanumeric Kanji Binary
M1 (11x11) L (Error detection
only)
5 - - -
M2 (13x13) L
M
10
8
6
5
-
-
-
-
M3 (15x15) L
M
23
18
14
11
6
4
9
7
M4 (17x17) L
M
Q
35
30
21
21
18
13
9
8
5
15
13
9
[Coding Example 3]
Error correction level: 7%, Size of one side of cell: 05, Data setup mode: Manual setup,
Concatenation mode: Normal, printed in version M4
<A>
<V>100<H>200<2D32>,L,05,0,0
<QV>4
<DS>1,012345
<DN>0004,6789
<Q>1
<Z>
[Supplementary Explanation4]
• Specify <QV> command between <2Dxx> and <DN>/<DS>.
• When resulted in a parameter error, it will be handled in the same manner of no specification.
• It does not become a parameter error from 00 to 40 (Set the value within the range
corresponding to each model).
For MicroQR, the setting range is from 00 to 04.
• Sending the data exceeding the data size of specified version will result in error and QR code is
not printed.