536
Name of Setting
item
Setting value Default Value R/W
initial
Contents of Setting item
IW
INNER_PEAP
"0":MSCHAPv2
"1":GTC
"2":MD5
"3":OTP
"4":TLS
"0":MSCHAPv2
R/W
â—‹
Inner Method if EAP Mode=PEAP
INNER_TTLS
"0":MSCHAPv2
"1":MSCHAP
"2":CHAP
"3":PAP
"4":EAP-GTC
"5":EAP-MD5
"6":EAP-MSCHAPv2
"7":EAP-OTP
"8":EAP
-
TLS
"0":MSCHAPv2
R/W
â—‹
Inner Method if EAP Mode=TTLS
EAP_USERNAME
0
-
63 digit long characters
NULL
R/W
â—‹
EAP authentication
user name
EAP_PASSWORD
0
-
32 digit long characters
*Encrypted data
String of empty
W
â—‹
EAP authentication password
EAP_ANON
0
-
63 digit long characters
NULL
R/W
â—‹
Anon. Outer ID
If EAP Mode=FASE,PEAP,TTLS
EAP_VERIFY
"0":Disable
"1":Enable
1
R/W
â—‹
Verify Server Cert.
Not for LEAP
EAP_PRIVATEKE
Y
0
-
64
digit long characters
*Encrypted data
String of empty
W
â—‹
Private Key P/W
EAP_AUTO_PAC
"0":Disable
"1":Enable
0
R/W
â—‹
PAC Auto Provi
si
oning
If EAP Mode=FAST
EAP_PAC_PASS
0
-
64bytes
* Encrypted data
String of empty
W
â—‹
PAC Password
If EAP=FAST & Auto prov.=off
SignalLevel1
-
85 dBm
-
R
-
Threshold for electrical field strength
1
SignalLevel2
-
74
dBm
-
R
-
Threshold for electrical field strength
2
SignalLevel3
-
64
dBm
-
R
-
Threshold for electrical field strength
3
Version
x.x.x.
-
R
-
Firmware
version for WLAN module
MACADDRESS
"AA:BB:CC:DD:EE:FF"
-
R
-
MAC address
WIFI_DEVICE_NA
ME
1
-
32 digit long characters
SATO_PRINTER
R/W
â—‹
Wi
-
Fi Direct Device Name
[BLUETOOTH] section
Name of Setting
item
Setting value Default Value R/W
initial
Contents
of Setting item
IB
BLUETOOTH
"0": Disable
"1": Enable
1
R/W
â—‹
Bluetooth
PROTOCOL
"0": status
3
"1": status 4
"2": NONE
1
R/W
â—‹
Communication
protocol (for SBPL)
BLUELEVEL
"0": No authentication
"1": Auth. level 2-1
"2": Auth. level 2-2
"3": Auth. level 3
"4": Auth. level 4
0
R/W
â—‹
Authentication level
PINCODE
0
-
16 digit characters (except '"')
*Encrypted data
0000
R/W
â—‹
PIN code
DEVICENAME
0
-
53
digit characters
SATO PRINTER
_ xxxxxxxxxxxx
R/W
â—‹
Device name
(xxxxxxxxxxxx is BD address)
ISI
"0"
,
"12"
to
"1000"(
hexadecimal
)
800
R/W
â—‹
ISI
value will be set to Bluetooth module
after deducting 1 from the value when
odd number is set with ISI
ISW
"0"
,
"11"
to
"1000"(
hexadecimal
)
12
R/W
â—‹
ISW
Set ISI≥ISW
PSI
"12"
to
"1000"(
hexadecimal
)
800
R/W
â—‹
PSI
value will be set to Bluetooth module
after deducting 1 from the value when
odd number is set with PSI
PSW
"11"
to
"1000"(
hexadecimal
)
12
R/W
â—‹
PSW
Set PSI≥PSW
BLUEADDRESS
"aabbccddeeff"
-
R
-
BD address
BLUEVERSION
"spp3_vX.YY"
-
R
-
Bluetooth
firmware version
CRC
"0": Disabled
"1": Enabled
0
R/W
â—‹
CRC
mode
PAIRING1
"0": Do not remove
"1": Remove
0
W
-
Remove paring
information1 or not
PAIRING2
"0": Do not remove
"1": Remove
0
W
-
Remove paring
information2 or not