5 Replacement
71
S84-ex/S86-ex Service Manual
7 Disconnect the sensor cable from the
defective top media sensor PCB and
replace with a new top media sensor
PCB.
8 Connect the sensor cable to the new top
media sensor PCB and attach the
new top media sensor PCB back to
the sensor holder .
9 To assemble the media sensor
cover , make sure that you insert the
tab of the media sensor cover to the
slot of the media sensor assembly .
Then, attach the media sensor cover
using the thumbscrew .
10
Remove two screws attaching the sensor bracket to the center frame.
11
Withdraw the sensor bracket .
Be careful not to pull the attached sensor cable.
12
Remove two screws attaching the
bottom media sensor PCB .
13
Disconnect the sensor cable from the
defective bottom media sensor PCB
and replace with a new bottom media
sensor PCB .
4
5
8
9
9
11
10