172
Persistence of
the command
When printer is powered off
Set parameter will not be retained
Retained until next valid setting
Retained until next valid setting
[Function]
Specifies print darkness.
[Format]
<#E>a(b)
●Parameter
a [Darkness level] = See table below.
b [Darkness range] = A (Omissible)
Use [A] for darkness range under normal conditions
[Coding Example]
<A>
<#E>3
<Z>
[Note]
1. The setting by this command will not persist after powering off the printer. When the printer restarted, either the printer’ default
value, or original values set by the command <PG> will be valid.
[Tips]
1. Invalid range being selected will result in a command error and the setting will not be changed.
2. The default values are available by the operation of the printer side.
[Default value and valid range]
1: Light
2: Slightly light
3: Normal
4: Slightly dark
5: Dark