188
, a, b, c, d, e, f, g, h, i, j
Persistence of the
command
When printer is powered off
Set Parameter will be retained
Retained until next valid setting
Retained until next valid setting
[Function]
Settings of : Auto-online, zero slash(Enable/Disable), protocol code, Euro code
[Format]
<LD>,a,b,c,d,e,f,g,h,i,j
● Parameter
See the table below.
[Coding Example]
<A>
<LD>,{,},%,#,&,=, - ,0,0,<FF>
16
<Z>
[Notes]
1. Place this command between Start code<A> and Stop code<Z>.
2. The command <LD> may be received while printer is in online mode.
3. Certain parameters may be omitted by giving “,” as place holder. Current valid setting will be applied to “,” position.
4. If more or less than 10 commas “,” is used, or specified code is used in other commands or in print data, the result may not be guaranteed.
5. After the setting by this command <LD> is successfully completed, setting information will be printed.
After the printing is completed, press the FEED/LINE key once and repower the printer to make the new settings valid. If the printer is powered off
without FEED/LINE key pressed, the setting information will not be saved.
6. Non-standard code set by this command <LD> will be enabled by the command <PG> or <PC>.