8. Edit Command
Persistence of the
command
When printer is powered off
Set parameter will not be retained
Set parameter will be retained until next valid setting
Set parameter will be the default value for the next job <A>
[Function]
Defines character pitch in dots
[Format]
<P>aa
● Parameter
a [Inter-character pitch] = Valid range : 00 to 99 dots
[Coding example] Inter-character pitch: 10
<A>
<V>100<H>200<P>10<L>0202<OA>ABCD
<Q>2
<Z>
[Notes]
1. The character pitch is the distance between characters, fonts when selecting barcode / font print.
2. The character pitch is enlarged according to the expansion factor <L>, if specified.
3. Even if automatic line feed is selected <E> and line feed code [CR] is set, the character pitch remains valid (saved) and the setting does not
return to default. Only if Start data transfer <A> is selected, the setting returns to default.
4. When setting the character pitch <P> directly before specifying a barcode print, the pitch command for the barcode module becomes valid.
Applicable barcodes: CODABAR (NW-7), CODE39, Industrial 2of5, Matrix 2of5
For details, refer to the [9. Barcode settings outline (3) inter-character gap].
5. If incorrect values are specified, the settings will return to default.
[Valid commands]
WS4 series