13
Control
Available for
WS4 series
ESC+ID Job ID Number
ESC+ID
Hex code
ESC
ID
Parameter
<1B>
16
<49>
16
<44>
16
aa
Default setting
aa=<20>
16
Persistence of
the command
When printer is powered off
Set parameter will not be retained
Validity in a job
Set parameter will be retained until next valid setting
Validity after a job
Becomes invalid after the job
[Function]
Defines job ID for status return
[Format]
<ID>aa
● Parameter
a [Job ID number] = Valid range : 00 - 99
[Coding example] Job ID number: 01
<A>
<ID>01
<V>200<H>100<P>0<$>B,100,100,6
<$=>SATOPRINTER
<Q>2
<Z>
[Notes]
1. If using a status return in the transfer protocol, the job ID number can be set in the telegram.
2. The status can be confirmed by putting out a status request (ENQ).
3. This command is set within the item, between start data transfer <A> and end data transfer <Z>.
[Important]
1. Activates when status return transfer protocol is used and status request (ENQ) is received during printing (incl. QTY≠0, offline,
error).
2. If status return transfer protocol is used, and status request is received while not printing (QTY=0, start up, no data received),
space (20H) will be set and returned as status.
3. If defining a job ID number several times during one item (between start data transfer <A> and end data transfer <Z>), the last
definition will be valid.
4. For more details, refer to the “Interface Specifications”.
Job ID Number