Minimum L
L2: Load < MIN
The current belt speed is lower than the set limit value.
Measures : Usually none, if the message L4 does not also occur or if
system-specific limits are to be observed.
Parameters : F 05, F 06
L4: LC Input < MIN
The weigh system load is too low and measuring is at risk.
Measures : Check the weigh bridge mechanics and alignment of the
measuring idlers. check the load cell cabling.
Parameter : O 09
Event messages