Translation of Original Operating Instructions
Airport Sweeper / Airport Stand Cleaner
2017-02-02 137
20.5.1 Filling the cleaning agent tank
DANGER
Injuries due to cleaning agent
► Avoid breathing in and swallowing the
cleaning agent, as well as contact with
the skin, eyes, etc.
See the manufacturer's specifications
NOTE
Damage to cleaning and water system
► Completely empty both systems in case of
a danger of frost
NOTE
Expiration of the warranty
► Cleaning agent (detergent) "BioVersal FW"
from BioVersal is approved by Aebi Schmidt
to prevent corrosion of the hopper and
fixtures.
Filling the cleaning agent tank (version 1)
Unscrew the cap (1) on the C connection.
Connect the filling hose.
Fill the cleaning agent tank slowly.
Visually monitor the filling process continually
at the fill level indicator (2) on the tank.
Stop the filling process before reaching
the maximum fill level.
Screw the cap (1) back onto the C connection.
Filling the cleaning agent tank (Version 2)
Open the tank cap (3)
Fill approximately 130 litres of cleaning agent
via the filling port (4). Monitor the fill level
indicator (5) during the process.
Screw the tank cap (3) back on.
20.5.2 Calling up kilometres and hours
Turn off auxiliary engine and start the ignition.
Press the INFO button (1).
Select total or daily data with the buttons (2).
The corresponding symbol bar (3/4) illuminates.