EasyManua.ls Logo

Schmidt AS 990 - Fuses

Schmidt AS 990
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Translation of Original Operating Instructions
Airport Sweeper / Airport Stand Cleaner
2017-02-02 43
7.10.2 Fuses
F1.1 / 30A
Maxi pre-fuse
F31 / 10A
PLC interface
F1.2 / 30A
Maxi pre-fuse
F31.1 / 5A
Hopper warning light
F2 / 3A
CR0020
F32 / 30A
Term. 30 engine control +
flame start
F10 / 10A
Term. 15 SCR module
F33 / 10A
Term. 30 ADM
F11 / 10A
Term. 15 engine control +
flame start
F34 / 10A
Term. 30 DC - diagnostic
connector
F12 / 15A
CR0020 outputs
F35 / 15A
Term. 15 engine
F13 / 3A
EMERGENCY STOP
F36 / 15A
Fuel preheating
F14 / 10A
Module 2 outputs
F37 / 5A
Electro-hydraulics
F15 / 10A
Module 3 outputs
F38 / 15A
Water tank heating
F16 / 10A
Module 4 outputs
F39 / 10A
Reversing light
F17 / 10A
Module 5 outputs
F40 / 15A
Term. 15 IVECO engine
F18 / 10A
Control panel
F41 / 15A
IVECO engine starter
F19 / 3A
Modules and sensors
F42 / 10A
Term. 15
F20 / 3A
Suction hose flap
F43 / 3A
Water tank heating
F21 / 3A
Hydraulic sprayer
F44 / 15A
Term. 30 SCR module
F22 / 15A
Rotary beacon
F45 / 20A
SSR 0105
F23 / 10A
Central lubrication
F46 / 10A
Additional I/0 module
F24 / 5A
2
n
d
working light, rear
F47 / 10A
Additional I/0 module
F25 / 25A
VKS oil cooler
FNK1 / 5A
Emergency function of hopper
F30 / 3A
EMERGENCY STOP
7.10.3 Battery isolator switch
NOTE
Electrics and electronics can be destroyed if
the battery cut-off is pressed when the engines
are running (vehicle and/or auxiliary engine).
The battery cut-off cuts the connection between the
battery and vehicle electrics. The may be pressed
only if the vehicle and auxiliary engines are shut
down.
The machine is not de-energised until an
approximate coastdown time of 3 minutes has
passed.
7.10.4 Remote start connector
The starting aid for the auxiliary engine can
be connected to the remote start connector.

Table of Contents