Translation of Original Operating Instructions
Airport Sweeper / Airport Stand Cleaner
2017-02-02 68
Connection has been established with the PLC controller
Start engine only after the menu screen appears.
DANGER
Poisoning
Do not let the engine run in enclosed spaces or
conduct away exhaust gases; provide proper
ventilation
Start engine
Turn the ignition key as far as it can be turned (1).
In the case of a cold start, the motor switches to a warm-
up phase. The symbol (2) on the display shows the
difference between the actual and target temperature of
the auxiliary engine. Sweep mode can be started and full
load can be used once this light goes out.
Ignition key (1) start switch settings:
A Ignition off, ignition key can be removed.
B Ignition off, ignition key cannot be removed.
C Ignition on.
D Start the auxiliary engine (hold for at least 3 s).
DANGER
Flying foreign bodies when the blower is started
(strange noise)
Safely shut down the vehicle and remove the
foreign bodies
Check the blower for damage.