CVT SYSTEM
3-6-13
Drive Pulley Inspection
◆
If the sheave surfaces
【
A
】
appear damaged,
replace the sheaves.
◆
Measure the inside diameter
【
B
】
and
【
C
】
of the
Bushings.
◆
If the Drive Move Pulley Bushing is damaged or
worn, replace the Drive Move Pulley.
Bushing 60×55×20 inside Diameter:
【
C
】
Standard: 55.005 ~ 55.095 mm (2.166" ~ 1.169")
Service Limit: 55.15 mm (2.171")
Bushing 36×32×15 inside Diameter:
【
B
】
Standard: 32.003 ~ 32.073 mm (1.260" ~ 1.263")
Service Limit: 32.11 mm (1.264")
◆
Check the Surface wear of the Counterweight
Shoes.
◆
If the Counterweight Shoes
【
D
】
are damaged,
replace them.
◆
Check the Shoes side clearance
◆
Measure the resulting clearance between the Thrust
Plate Shoes
【
B
】
and the post
【
C
】
on the movable
sheave at all three positions as shown.
★
If any of the measurements are greater than the
maximum, replace all shoes with standard shoes.
Shoes side clearance:
Standard: 0.15~ 0.30 mm (0.0059" ~ 0.0118")
B
C
A
D
F
E