COOLING SYSTEM
6 - 5
Technical Parameter
Item Standard Service Limit
Coolant provided during
transportation:
Type
Color
Mixing ratio
Total
Permanent antifreeze (soft water and glycol for
aluminum engines and radiators plus corrosion
inhibitors and rust inhibitor chemicals)
Green
Soft water 50%, cooling water 50%
3.4 L
(
3.6US qt
)
(Full level of the water storage
tank, including radiator and engine )
– – –
– – –
– – –
– – –
Radiator cover
– – –
Pressure relief 93~123 kPa(0.95~1.25 kgf /cm
2
,14~18psi)
Thermostat
Valve opening temperature 79~82
0
C(174.2~179.6
0
F)
– – –
Valve fully open lift 8~12mm or over 85
o
C(185
o
F)
– – –
Coolant fi lter/valve
Cooling valve closing
temperature(For reference)
83
o
C(181.4
0
F)or over 24.5kPa(0.25kgf/cm
2
,
3.6 psi)
– – –