ELECTRICAL SYSTEM
14 - 20
DC
B
A
Troubleshooting
The electronic control unit ECU monitors various sensors, actuators, power amplifier circuits and
detection circuits. Common fault codes are shown in the fault list.
!
When the fault of oxygen sensor signal is checked, the engine should be run for at least 5-10min to
ensure the completion of heating of oxygen sensor.
Oxygen sensor failure check:
Check whether the oxygen sensor connector is well connected
Unplug the connector, check whether the sensor and the wire harness end pins are bent or
deformed, etc.
Check whether the resistance between pinsBandDis normal
Check whether the voltage between pinBand the main relay is normal
Connect the connector and run the engine for a period of time, check whether the voltage between
pinsAandCis normal.
In addition, the oxygen sensor is an indirect refl ection sensor. If other sensors are faulty, the
oxygen sensor will also report a fault:
Unreliable battery voltage
The absolute pressure signal of the intake manifold is unreliable
The signal of the engine temperature sensor is unreliable
Injector driver stage failure
!
When disassembling the oxygen sensor, be careful of the mu er and engine, and be careful of burns!