Chapter 5 Operating Instructions
C 4000 Standard/Advanced
42 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8 009 861/OE59/19-11-04
Installation and mounting
Sender and receiver can be mounted in two different ways:
$ mounting with swivel mount bracket
$ mounting with side bracket
5.2.1 Mounting with swivel mount bracket
The swivel mount bracket is made of black polyamide PA6. The bracket is designed such
that sender and receiver can still be accurately aligned even after the bracket has been
mounted.
The swivel mount bracket is also suitable for mounting the deflector mirrors PNS 75 and
PNS 125 (see chapter 11.4.6)f. on page 77)f.).
Attach the bolts of the swivel mount bracket with a torque of between 2.5 and 3 Nm.
Higher torques can damage the bracket; lower torques provide inadequate protection
against vibration.
Note
Fig. 24: Composition of the
swivel mount bracket
Part No. 2 019 659