Operating Instructions Chapter 12
C4000 Select
8012247/RI61/2007-11-30 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 71
Ordering information
12.3 C4000 Select with integrated LED status indicator
T
he following table provides part number and model designation information for C4000
Select sender and receiver units that may be used in standalone operation (as single sys-
tem) or as the last segment (guest) of a cascaded system. An LED indicator (360° view)
t
hat provides safety output status information is integrated into the top end cap of the
C4000 Select receiver unit.
Part numbers and model designationsProtective field
height [mm]
Sender only Receiver only
Sender and
receiver
300
1204061
(XC40S-0303A0A00AA0)
1204139
(XC40E-0303A0A0AAC0)
1043117
(XC40P-0303A0A0AAC0)
600
1204068
(XC40S-0603A0A00AA0)
1204140
(XC40E-0603A0A0AAC0)
1043118
(XC40P-0603A0A0AAC0)
900
1204071
(XC40S-0903A0A00AA0)
1204141
(XC40E-0903A0A0AAC0)
1043119
(XC40P-0903A0A0AAC0)
1200
1204118
(XC40S-1203A0A00AA0)
1204142
(XC40E-1203A0A0AAC0)
1043120
(XC40P-1203A0A0AAC0)
1500
1204119
(XC40S-1503A0A00AA0)
1204143
(XC40E-1503A0A0AAC0)
1043121
(XC40P-1503A0A0AAC0)
1800
1204112
(XC40S-1803A0A00AA0)
1204144
(XC40E-1803A0A0AAC0)
1043122
(XC40P-1803A0A0AAC0)
12.4 C4000 Select with top end cap extension connection
The following table provides part number and model designation information for C4000
Select sender and receiver units that may be used in standalone operation (as single sys-
tem) or as a host segment, first guest segment or the last guest segment of a cascaded
system. An extension connection is incorporated into the top end cap of the devices for
connection of extended I/O devices. The system connection is located in the bottom end
cap of the devices.
Part numbers and model designationsProtective field
height [mm]
Sender only Receiver only
Sender and
receiver
300
1204069
(XC40S-0303A0A00AB0)
1204134
(XC40E-0303A0A0CAB0)
1043123
(XC40P-0303A0A0CAB0)
600
1204132
(XC40S-0603A0A00AB0)
1204146
(XC40E-0603A0A0CAB0)
1043124
(XC40P-0603A0A0CAB0)
900
1204145
(XC40S-0903A0A00AB0)
1204147
(XC40E-0903A0A0CAB0)
1043125
(XC40P-0903A0A0CAB0)
1200
1204148
(XC40S-1203A0A00AB0)
1204149
(XC40E-1203A0A0CAB0)
1043126
(XC40P-1203A0A0CAB0)
1500
1204150
(XC40S-1503A0A00AB0)
1204151
(XC40E-1503A0A0CAB0)
1043127
(XC40P-1503A0A0CAB0)
1800
1204152
(XC40S-1803A0A00AB0)
1204153
(XC40E-1803A0A0CAB0)
1043128
(XC40P-1803A0A0CAB0)
Tab.
45
:
C4000 Select
without extension connection
and integrated LED status
indicator on the receiver unit
Tab.
46
:
C4000 Select
with
top end cap extension con-
nection

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK C4000 Select and is the answer not in the manual?

SICK C4000 Select Specifications

General IconGeneral
TypeSafety Light Curtain
Safety Integrity LevelSIL3
Performance LevelPL e
Enclosure RatingIP65
CategoryCategory 4
Light SourceInfrared LED
Operating Voltage24 V DC
Protection ClassIII
Resolution14 mm, 30 mm
Protective Field Height300 mm to 1800 mm
Operating Range0.5m to 9m
Supply Voltage24 V DC
Operating Temperature-30 °C to +55 °C
SynchronizationOptical, via cable
Beam Divergence2.5°
Housing MaterialAluminum
Ambient Temperature Range-25 °C ... +55 °C
Output TypePNP