EasyManuals Logo

SICK C4000 Select User Manual

SICK C4000 Select
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
Operating Instructions Chapter 2
C4000 Select
8012247/RI61/2007-11-30 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 9
On safety
2 On safety
This chapter deals with your own safety and the safety of the equipment operators.
Please read this chapter carefully before working with the C4000 Select or with the
machine protected by the C4000 Select.
2.1 Qualified safety personnel
The C4000 Select safety light curtain must be installed, connected, commissioned and
serviced only by qualified safety personnel. Qualified safety personnel are defined as
persons who …
due to their specialist training and experience have adequate knowledge of the power-
driven equipment to be checked
and
who have been instructed by the responsible machine operator in the operation of the
machine and the current valid safety guidelines
and
are sufficiently familiar with the applicable official health and safety regulations,
directives and generally recognized engineering practice (e.g. DIN standards, VDE
stipulations, engineering regulations from other EC member states) that they can
assess the work safety aspects of the power-driven equipment
and
who have access to these operating instructions and who have read and understood
them.
As a rule these are qualified safety personnel from the ESPE manufacturer or also those
persons who have been appropriately trained at the ESPE manufacturer, are primarily
involved in checking ESPE and are allocated the task by the organization operating the
ESPE.
2.2 Applications of the device
The C4000 Select safety light curtain is an electro-sensitive protective equipment (ESPE)
rated to:
type 4 in accordance with IEC 61496@1 and @2
SIL 3 in accordance with IEC 61508 and IEC 62061
category 4 in accordance with EN 954@1:1997
performance level “e” in accordance with EN ISO 13849@1:2006
The physical resolution of the C4000 Select is 30 mm with a maximum protective field
width of up to 21 m and available protective field heights from 300 up to 1800 mm. Con-
figurable parameters are set using DIP switches.
The device is suitable for:
hazardous point protection (hand protection)
hazardous area protection
access protection

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK C4000 Select and is the answer not in the manual?

SICK C4000 Select Specifications

General IconGeneral
TypeSafety Light Curtain
Safety Integrity LevelSIL3
Performance LevelPL e
Enclosure RatingIP65
CategoryCategory 4
Light SourceInfrared LED
Operating Voltage24 V DC
Protection ClassIII
Resolution14 mm, 30 mm
Protective Field Height300 mm to 1800 mm
Operating Range0.5m to 9m
Supply Voltage24 V DC
Operating Temperature-30 °C to +55 °C
SynchronizationOptical, via cable
Beam Divergence2.5°
Housing MaterialAluminum
Ambient Temperature Range-25 °C ... +55 °C
Output TypePNP