EasyManuals Logo

SICK C4000 Select User Manual

SICK C4000 Select
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
Operating Instructions Chapter 12
C4000 Select
8012247/RI61/2007-11-30 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 73
Ordering information
12.7 C4000 Select with bottom extension connection
(receiver only)
The following table provides part number and model designation information for C4000
S
elect sender and receiver units that may be used in a system extending a S300 or S3000
safety laser scanner. The extension and system connections are both incorporated into the
bottom end cap of the devices.
Part numbers and model designationsProtective field
height [mm]
Sender only Receiver only
Sender and
receiver
300
1204061
(XC40S-0303A0A00AA0)
1204155
(XC40E-0303A0A0CBA0)
1043141
(XC40P-0303A0A0CCA0)
600
1204068
(XC40S-0603A0A00AA0)
1204157
(XC40E-0603A0A0CBA0)
1043142
(XC40P-0603A0A0CCA0)
900
1204071
(XC40S-0903A0A00AA0)
1204159
(XC40E-0903A0A0CBA0)
1043143
(XC40P-0903A0A0CCA0)
1200
1204118
(XC40S-1203A0A00AA0)
1204161
(XC40E-1203A0A0CBA0)
1043144
(XC40P-1203A0A0CCA0)
1500
1204119
(XC40S-1503A0A00AA0)
1204163
(XC40E-1503A0A0CBA0)
1043145
(XC40P-1503A0A0CCA0)
1800
1204112
(XC40S-1803A0A00AA0)
1204165
(XC40E-1803A0A0CBA0)
1043146
(XC40P-1803A0A0CCA0)
12.8 C4000 Select with bottom extension connection and
integrated LED status indicator (receiver only)
The following table provides part number and model designation information for C4000
Select sender and receiver units that may be used in a system extending a S300 or S3000
safety laser scanner. The extension and system connections are both incorporated into the
bottom end cap of the devices. An LED indicator (360° view) that provides safety output
status information is integrated into the top end cap of the C4000 Select receiver unit.
Part numbers and model designationsProtective field
height [mm]
Sender only Receiver only
Sender and
receiver
300
1204061
(XC40S-0303A0A00AA0)
1204166
(XC40E-0303A0A0CBC0)
1043147
(XC40P-0303A0A0CCC0)
600
1204068
(XC40S-0603A0A00AA0)
1204167
(XC40E-0603A0A0CBC0)
1043148
(XC40P-0603A0A0CCC0)
900
1204071
(XC40S-0903A0A00AA0)
1204168
(XC40E-0903A0A0CBC0)
1043149
(XC40P-0903A0A0CCC0)
1200
1204118
(XC40S-1203A0A00AA0)
1204169
(XC40E-1203A0A0CBC0)
1043150
(XC40P-1203A0A0CCC0)
1500
1204119
(XC40S-1503A0A00AA0)
1204170
(XC40E-1503A0A0CBC0)
1043151
(XC40P-1503A0A0CCC0)
1800
1204112
(XC40S-1803A0A00AA0)
1204171
(XC40E-1803A0A0CBC0)
1043152
(XC40P-1803A0A0CCC0)
Tab.
49
:
C4000 Select
with
bottom end cap extension
connection (receiver only)
Tab.
50
:
C4000 Select
with
bottom end cap extension
connection and integrated
LED status indicator (receiver
only)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK C4000 Select and is the answer not in the manual?

SICK C4000 Select Specifications

General IconGeneral
TypeSafety Light Curtain
Safety Integrity LevelSIL3
Performance LevelPL e
Enclosure RatingIP65
CategoryCategory 4
Light SourceInfrared LED
Operating Voltage24 V DC
Protection ClassIII
Resolution14 mm, 30 mm
Protective Field Height300 mm to 1800 mm
Operating Range0.5m to 9m
Supply Voltage24 V DC
Operating Temperature-30 °C to +55 °C
SynchronizationOptical, via cable
Beam Divergence2.5°
Housing MaterialAluminum
Ambient Temperature Range-25 °C ... +55 °C
Output TypePNP