Chapter 1 Operating Instructions
C4000 Select
8 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8012247/RI61/2007-11-30
About this document
The term “dangerous state
The dangerous state (standard term) of the machine is always shown in the drawings and
d
iagrams of this document as the movement of a machine part. In practical operation,
there may be a number of different dangerous states:
machine movements
electrical conductors
visible or invisible radiation
a combination of several risks and hazards

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK C4000 Select and is the answer not in the manual?

SICK C4000 Select Specifications

General IconGeneral
TypeSafety Light Curtain
Safety Integrity LevelSIL3
Performance LevelPL e
Enclosure RatingIP65
CategoryCategory 4
Light SourceInfrared LED
Operating Voltage24 V DC
Protection ClassIII
Resolution14 mm, 30 mm
Protective Field Height300 mm to 1800 mm
Operating Range0.5m to 9m
Supply Voltage24 V DC
Operating Temperature-30 °C to +55 °C
SynchronizationOptical, via cable
Beam Divergence2.5°
Housing MaterialAluminum
Ambient Temperature Range-25 °C ... +55 °C
Output TypePNP