microScan3 Core – Ether‐
Ne
t/IP™
microScan3 Pro – Ether‐
Net/IP™
Class
5M1 (IE
C60721-3-5)
3M4 (IECTR60721-4-3)
Sinusoidal vibrations
50m/s², 0.35mm, 10Hz … 150Hz
5m/s², 1.5mm, 5Hz … 200Hz
10m/s², 3.5mm, 5Hz … 150Hz
Noise vibrations
0.5m²/s³, 5Hz … 200Hz
0.1m²/s³, 200Hz … 500Hz
Shock resistance
5)
Standards
IE
C 60068-2-27
IEC 60721-3-5
IEC TR 60721-4-3
IEC 61496-1
IEC 61496-3
Class
5M1 (IE
C60721-3-5)
3M4 (IECTR60721-4-3)
Single shock 50m/s², 11ms
Continuous shock
100m/s², 16ms
150m/s², 6ms
EMC In accordance with IEC61496-1, IEC61000-6-2, and
IE
C61000-6-4
1)
The specified enclosure rating is only valid if the safety laser scanner is closed, the system plug and
t
he cover plate are mounted, and all of the M12 plug connectors of the safety laser scanner have been
closed using a cable plug connector suitable for the enclosure rating or using a protective cap.
2)
For ambient light sources directly in the scan plane in accordance with IEC61496-3: ≤3klx.
3)
IEC 61496-1, no. 4.3.1 and no. 5.4.2, IEC 61496-3, no. 4.3.1 and no. 5.4.2. Condensation has an
influence on normal operation.
4)
IEC61496-1, no. 4.3.1 and no. 5.4.2, IEC61496-3, no. 4.3.1 and no. 5.4.2. Condensation has an
influence on normal operation.
5)
In direct mounting.
Miscellaneous data
T
able 47: Miscellaneous data
microScan3 Core – Ether‐
Ne
t/IP™
microScan3 Pro – Ether‐
Net/IP™
Wavelength 845nm
Detectable remission 1.8% … several 1000% 1.8% to several 1,000%
Maximum uniform contami‐
na
tion of the optics cover
without reducing the detec‐
tion capability
1)
30%
Area where detection capabil‐
ity is restricted
≤50mm
2)
Divergence of collimated
be
am
0.17°
Receiving angle 0.75°
Pulse duration Typ. 4ns
Average output power 9.2mW
TECHNICAL DATA 13
8020200/1NTM/2024-06-03 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™