Services
•
G
et_Attribute_Single
•
Set_Attribute_Single
•
Safety Reset
°
Type 0: Completely restart device
24)
.
Available instances
•
ID1
13.9.1.5 Safety validator object (0x3A)
Object class
Attribute ID Access rule Name Data type
Dec Hex
8 0x08 Get Safety Connection
Fault Count
UINT
Services
•
G
et_Attribute_Single
•
Reset All Error Counters
Object instance
Attribute ID Access rule Name Data type
Dec Hex
1 0x01 Get Safety Validator State USINT
2 0x02 Get Safety Validator Type USINT
3 0x03 Get Ping Interval EPI Multi‐
plier
UINT
7 0x07 Get Max Consumer Num‐
ber
USINT
12 0x0C Set
1)
Max Data Age UINT
13 0x0D Get Application Data Path EPATH
15 0x0F Get Producer/Consumer
F
ault Counters
STRUCT
1)
The value can only be set to 0.
Services
•
G
et_Attribute_Single
•
Set_Attribute_Single
Available instances
•
ID1
•
…
•
ID58
13.9.1.6 DLR object (device level ring) (0x47)
Object class
Attribute ID Access rule Name Data type
Dec Hex
1 0x01 Get Revision UINT
Services
•
G
et_Attribute_Single
24)
T
he device can only be restarted in this way if no CIP Safety connections to the device exist yet
13 T
ECHNICAL DATA
186
O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™ 8020200/1NTM/2024-06-03 | SICK
Subject to change without notice