Annex
94 © SICK AG · Division Auto Ident · Germany · Subject to change without notice 8013796/UL20/2010-09-27
Operating Instructions
Laser Measurement Systems of the LMS500 Product Family
Chapter 10
10.2.12 Start the device/logout
The device is returned to the measurement mode after configuration.
Request
Message structure: sMN Run
Answer
Message structure: sAN Run ErrorCode
Example
Request: <STX>sMN{SPC}Run<ETX>
Answer: <STX>sAN{SPC}Run{SPC}0<ETX>
Message part Description Variable type Length
(byte)
Value range
Type of command Request (SOPAS method by name) string 3 sMN
Command Start the device string 3 Run
Message syntax XXV: Request “Start device”
Message part Description Variable type Length
(byte)
Value range
Type of command Answer (SOPAS answer) string 3 sAN
Command Start the device string 3 Run
ErrorCode The command has been accepted
if the error code 0 is returned.
Bool 1 0 error
1 no error
Message syntax XXVI: Answer to the “Start device” request

Table of Contents